en | System Informations 1
Digit Required
0
1
2
3
4
5
6
7
Table 7.1 Dialing Digits
To program the IP Address and port:
Use no punctuation in IP address. If any unit of IP address is less than 3 digits, use 0 to fulfill
the data in the higher bits. The remaining 5 digits will program the port. Port number ranges
from 0-65535. Any port is less than 5 digits, use 0 to fulfill the data.
Example
To program the IP Address 10.16.1.222:80 as the IP
Address of Receiver 1, enter the following sequence into Location 000 - 016:[0 1 0 0 1 6 0
0 1 2 2 2 0 0 0 8 0]
NOTICE!
Programming option anti-replay, acknowledge wait time and pulse interval time are only used
in Bosch network format.
7.7.1

Telephone number for Receiver 1 - 4/IP Address and Port

(Refer to Section 10.1.1 Receiver Parameters, page 78). When the corresponding data format
for above programming address is a network communication format, it is explained as an IP
Address and Port. For a non network format, it is explained as telephone number.
When the control panel transmits a report, it dials the telephone number/IP Address to
contact the monitoring station. If the call is successful, the relevant information is transmitted
and the dialer returns to Standby Mode.
Contact your monitoring station for the correct telephone number/IP Address before you
program these locations.
7.7.2

Other Network Programming Option

(Refer to Section 10.1.1 Receiver Parameters, page 78). When the control panel tansmits a
report in network , the following options should be programmed other than the IP Address
and port:
Anti-Replay:
Anti-replay prevents unauthorized messages from being sent to the CMS and being recognized
as originating from the control panel.
Contact your central monitoring station for the correct setting.
Acknowledge Wait Time
When no callback from the receiver after the acknowledge time is reached, the control panel
takes it as an unsuccessful communication and makes another attempt. The time ranges from
5 to 99 sec.
Contact your central monitoring station for the correct setting.
Pulse Interval Time
F.01U.241.127 | V4 | 2011.12
Number to Program
Digit Required
0
8
1
9
2
*
3
#
4
4 sec pause
5
Terminal
6
7
Installation Manual
AMAX panel 2000 / AMAX panel 2000 EN
Number to Program
8
9
11
12
13
15