Time Set - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Result
The method of obtaining the system time is configured.
Further notes
You display the settings for the system clock with the
5.1.3.2

time set

Description
With this command, you set the system clock.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time set hh:mm:ss <day (1-31)>
{january|february|march|april|may|june|july|august|september|october|november|decembe
r}
<year (2000 - 2035)>
The parameters have the following meaning:
Parameter
hh:mm:ss
day
-
year
Result
The system time is set.
Further notes
You display the settings for the system clock with the
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Description
Range of values
Time of day
Hour, minute, second each separated by ":" no link
Day of the month
1 ... 31
Month
january, february, march, april, may, june, july,
august, september, october, november, december
Year
2000 ... 2035
5.1 System time setting
command.
show time
command.
show time
System time
119

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr-500

Table of Contents