12.1.13.2

cabletest interface

Description
With this command, you enable the cable test for the specified interface.
Requirement
● The interface has no active data traffic
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command without parameters / with the following parameter assignment:
cabletest interface <iftype> <if-id> [force]
The parameters have the following meaning:
Parameter
iftype
if-id
force
If you do not select any parameters from the parameter list, the default value is used.
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 30)".
Result
Following the test phase, the result is displayed.
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Description
Type of interface
Interface identifier
Forces a
during the test
link down
Diagnostics
12.1 Event and fault handling
Range of values / note
Necessary parameter if there is
a
on the interface.
link up