Arp Timeout - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Network protocols
7.8 ARP
7.8.2.3

arp timeout

Description
With this command, you configure the timeout setting of the ARP cache.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
arp timeout <seconds(30-86400)>
The parameter has the following meaning:
Parameter
seconds
Result
The setting for the timeout setting of the ARP cache is configured.
Further notes
You can reset the timeout setting to the default with the
You can display the status of this function and other information with the
command.
310
Description
Value for the timeout in seconds
no arp timeout
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Range of values
30 ... 86400
Default: 300
command.
show ip arp

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr-500

Table of Contents