Set Sntp Unicast-Poll-Interval - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

5.3.5.3

set sntp unicast-poll-interval

Description
With this command, you configure the polling interval of the SNTP client in the unicast mode.
Requirement
● The addressing mode of the SNTP client is configured as "unicast".
You are in the SNTP Configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
set sntp unicast-poll-interval<value(16-16284)seconds>
The parameter has the following meaning:
Parameter
value
Result
The polling interval of the SNTP client in unicast mode is configured.
Further notes
You display this setting and other information with the
command.
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Description
Specifies the length of the polling interval in
seconds
Range of values
16 ... 16284
Default: 64
show sntp unicast–mode status
System time
5.3 SNTP client
133