Layer 2 management protocols
8.4 Ring redundancy and standby connection
Syntax
Call the command without parameters:
no standby force-master
Result
The standby force-master function is disabled.
Further notes
You enable the setting with the
You can display the status of this function and other information with the
redundancy
8.4.6.6

standby port

Description
With this command, you configure and enable the port for a standby connection on a device.
Requirement
You are in the Redundancy Configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
standby port {<iftype> <ifnum>}
The parameters have the following meaning:
Parameter
<iftype>
<ifnum>
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 30)".
Result
The ports for a standby connection are configured and enabled.
342
standby force-master
command.
Description
Type of interface
Slot no. and port no. of the interface
command.
Range of values
gigabitethernet
extreme-ethernet
Enter a valid interface name