Diagnostics
12.3 RMON
The parameter has the following meaning:
Parameters
index
Result
The entry is deleted.
12.3.2.5

set rmon

Description
With this command, you enable / disable the remote monitoring function.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
set rmon {enable|disable}
The parameters have the following meaning:
Parameter
enable
disable
Result
The remote monitoring function is enabled or disabled.
Further notes
You can display the status of this function and other information with the
rmon
576
Description
Number of the event entry to be deleted
command.
Description
Enables the remote monitoring function
Disables the remote monitoring function
Default: disabled
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Range of values
1 ... 52