12.1.14.4

event config

Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
● Message if there is cold or warm restart
● Message when there is a status change on a physical interface
● Message if there is an incorrect login
● Message when there is aRemote Monitoring (RMON) alarm
● Message when there is a status change in the power supply
● Message when there is a status change in the redundancy manager (RM)
● Message when there is a status change on a standby connection
● Message when there is a status change in the error monitoring
● Message when there is a change in the spanning tree
● Message on status change of the VRRP routers
● Message if there is a status change in the detection of network loops
● Message on status change of OSPF routers
These messages can be processed by the clients in different ways:
● Entry in the logbook of the device
● Sending the message to the log server of the system
● Sending an e-mail
● Sending an SNMP trap
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
event config
stp-change|vrrp-state-change|loopd-state-change|ospf-state-change|all}
{logtable|syslog|email|trap|faults|all}
The parameters have the following meaning:
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
{cold-warmstart|linkchange|authentication-failure|
rmon-alarm|power-change|rm-state-change|standby-state-change|faultstate-change|
Diagnostics
12.1 Event and fault handling
555