3.1.10.4

no cli-console-timeout

Description
With this command, you disable the automatic logout.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no cli-console-timeout
Result
Automatic logout is disabled.
Further notes
You enable automatic logout with the
3.1.10.5

coordinates height

Description
With this command, you enter a height coordinate.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
coordinates height <meter>
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
command.
cli-console-timeout
Configuration
3.1 System
61