No Link - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Diagnostics
12.1 Event and fault handling
Parameters
up
down
ifXtyp
iface_list
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 30)".
If you do not select an interface, the function is enabled for all available interfaces.
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You display the setting with the
You disable the function with the
12.1.14.13

no link

Description
With this command, you disable the monitoring of the physical network connections for cable
breaks or for pulling of the connector.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no {up|down}[{<ifXtype><iface_list>}]
564
Description
Only the establishment of a connection is signaled
Only a break on a connection is signaled
Type or speed of the interface
Slot no. and port no. of the interface
show events faults config
no link
command.
command.
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Range of values
-
-
gigabitethernet
extreme-ethernet
Enter a valid interface name