Datalogic Handheld Data Format Requirements
The following sections describe label transmission formats that are typically observed in factory configurations of
Datalogic handheld scanners.
RSS-14
•
Prefix must be ASCII characters 'R4'
•
Check character must be included in label
•
Application identifier "01" must follow the prefix and preceed the base label
•
Label length excluding prefix characters must be 16 characters.
•
Example: 'R40101044123456789'
RSS Expanded
•
Prefix must be ASCII characters 'R4'
•
Check character must be included in label
UPC-A
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Prefix must be an ASCII character 'A' - total length including prefix must be 13.
•
Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII character 'A' - total length including prefix must be 15.
•
Example: 'A06099201118712'.
UPC-A with 5-Digit Supplemental
•
Number system must be included in label data
•
Check digit must be included in label data and is assumed to be correct
•
Prefix must be an ASCII character 'A' - total length including prefix must be 18
•
Example: 'A06099201118712345'
UPC-A with Code 128 Supplemental
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Supplemental data is appended to base label.
188
Magellan
TM
3300HSi