Datalogic Handheld Data Format Requirements; 188; Rss Expanded; Upc-A - Datalogic magellan 3300HSI Product Reference Manual

In-counter horizontal single plane scanner
Hide thumbs Also See for magellan 3300HSI:
Table of Contents

Advertisement

Datalogic Handheld Data Format Requirements

The following sections describe label transmission formats that are typically observed in factory configurations of
Datalogic handheld scanners.
RSS-14
Prefix must be ASCII characters 'R4'
Check character must be included in label
Application identifier "01" must follow the prefix and preceed the base label
Label length excluding prefix characters must be 16 characters.
Example: 'R40101044123456789'

RSS Expanded

Prefix must be ASCII characters 'R4'
Check character must be included in label

UPC-A

Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Prefix must be an ASCII character 'A' - total length including prefix must be 13.
Example: 'A060992011187'.

UPC-A with 2-Digit Supplemental

Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including prefix must be 15.
Example: 'A06099201118712'.

UPC-A with 5-Digit Supplemental

Number system must be included in label data
Check digit must be included in label data and is assumed to be correct
Prefix must be an ASCII character 'A' - total length including prefix must be 18
Example: 'A06099201118712345'

UPC-A with Code 128 Supplemental

Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.

188

Magellan
TM
3300HSi

Advertisement

Table of Contents
loading

Table of Contents