Datalogic Handheld Data Format Requirements; 188; Rss-14; Rss Expanded - Datalogic Magellan 3200VSi Product Reference Manual

On-counter vertical presentation scanner
Hide thumbs Also See for Magellan 3200VSi:
Table of Contents

Advertisement

Datalogic Handheld Data Format Requirements

The following sections describe label transmission formats that are typically observed in factory configurations of
Datalogic handheld scanners.

RSS-14

Prefix must be ASCII characters 'R4'
Check character must be included in label
Application identifier "01" must follow the prefix and preceed the base label
Label length excluding prefix characters must be 16 characters.
Example: 'R40101044123456789'

RSS Expanded

Prefix must be ASCII characters 'R4'
Check character must be included in label

UPC-A

Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Prefix must be an ASCII character 'A' - total length including prefix must be 13.
Example: 'A060992011187'.

UPC-A with 2-Digit Supplemental

Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including prefix must be 15.
Example: 'A06099201118712'.

UPC-A with 5-Digit Supplemental

Number system must be included in label data
Check digit must be included in label data and is assumed to be correct
Prefix must be an ASCII character 'A' - total length including prefix must be 18
Example: 'A06099201118712345'

UPC-A with Code 128 Supplemental

Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.