6 PLC PROGRAM USED FOR POSITIONING CONTROL

6.3 Creating a program

6.3.1 General configuration of program

The "positioning control operation program" actually used is explained in this chapter.
The functions and programs explained in Section 2 are assembled into the "positioning
control operation program" explained here. (To monitor the control, add the required
monitor program that matches the system. Refer to Section 5.6 "List of monitor data"
for details on the monitor items.)
The general configuration of the "positioning control operation program" is shown
below.
Start of program creation
Parameter and
data are...
Set using GX
Configurator-QP
Initialization program
Start details setting program
Start program
JOG operation program
Inching operation program
Manual pulse generator
operation program
Sub program
Stop program
Completion of program
creation
Set using the PLC program
Parameter and data setting program
Servo parameter
Program for carrying out initialization
Program required to carry out "OPR control",
"major positioning control" and "high-level positioning control"
Program required to carry out "manual control"
Program required for
"sub functions" and "common functions"
Program for stopping control
6 - 15