Manual Pulse Generator Operation Execution Procedure - Mitsubishi Electric QD75MH1 User Manual

Type qd75mh positioning module
Table of Contents

Advertisement

11 MANUAL CONTROL

11.4.2 Manual pulse generator operation execution procedure

Preparation
Manual pulse
generator operation
start
Monitoring of the
manual pulse
generator operation
Manual pulse
generator operation
stop
The manual pulse generator operation is carried out by the following procedure.
STEP 1
Set the positioning parameters
Refer to Chapter 5
and Section 11.4.3.
STEP 2
Set " Cd. 20 Manual pulse generator 1 pulse input
magnification". (control data setting)
Refer to Section
11.4.4.
Create a PLC program in which the enable/disable is
set for the manual pulse generator operation.
(" Cd. 21 Manual pulse generator enable flag" setting.)
STEP 3
Write the PLC program to the PLC CPU.
STEP 4
Issue a command to enable the manual pulse generator
operation, and input the signals from the manual pulse
generator.
STEP 5
Monitor the manual pulse generator operation.
STEP 6
End the input from the manual pulse generator,
and issue a command to disable the manual pulse
End of control
REMARK
Mechanical elements such as limit switches are considered as already installed.
Positioning parameter settings work in common for all control using the QD75MH.
Pr.1
to
)
Pr.24
11 - 31
MELSEC-Q
One of the following two methods can be used.
<Method 1>
Directly set (write) the parameters in the QD75MH using
GX Configurator-QP.
<Method 2>
Set (write) the parameters from the PLC CPU to the
QD75MH using the PLC program (TO command).
Using GX Developer, set the control data and create a
PLC program to enable/disable the manual pulse
generator operation. (Set the control data in the QD75MH
buffer memory using the TO command.)
Write the PLC program created in STEP 1 and
STEP 2 to the PLC CPU using GX Developer.
Write "1" in " Cd.21 Manual pulse generator enable
flag", and operate the manual pulse generator.
One of the following two methods can be used.
<Method 1>
Monitor using GX Configurator-QP.
<Method 2>
Monitor using GX Developer.
Stop operating the manual pulse generator, and write "0"
in " Cd. 21 Manual pulse generator enable flag".