12 CONTROL SUB FUNCTIONS
Setting item
Operation setting
for incompletion of
Pr.55
OPR
Refer to Section 5.2.6 "OPR detailed parameters" for details on the setting details.
(2) When OPR request flag (
result in an "Home positioning return (OPR) request flag ON" error (error
code: 207) despite the setting value of "
incompletion of OPR", and Fast OPR will not be performed.
[3] Setting method of "Operation setting for incompletion of OPR"
The use the "Operation setting for incompletion of OPR", set the following
parameters using a PLC program.
Setting
value
Set the operation setting for incompletion of
OPR.
Md.31
Status: b3) is ON, starting Fast OPR will
Setting details
0: Positioning control is not executed.
1: Positioning control is executed.
12 - 104
MELSEC-Q
Pr.55
Operation setting for
Buffer memory address
Axis
Axis
1
87
237 387 537
Axis
Axis
2
3
4