Mitsubishi Electric QD75MH1 User Manual page 359

Type qd75mh positioning module
Table of Contents

Advertisement

7 MEMORY CONFIGURATION AND DATA PROCESS
Communication
operation status
with servo amplifer
Servo parameter of
buffer memory
1 : The servo parameter that it is stored into the flash ROM is transfered to the buffer memory by the QD75MH
initialization of the data, when the power is turned ON.
2 : Communication with servo amplifer is carried out if the QD75MH initialization of the data is completed after
power supply ON.
3 : When the servo parameter is written in the flash ROM, it is unnecessary to use a setup from the PLC program.
Fig. 7.1 Operation timing in the servo parameter transfer of the buffer memory
How to transfer the servo parameter which wrote it in the flash ROM
to servo amplifier
Flash ROM writing carried out after the servo parameter is set up in the buffer
memory.
After that, when the power is turned ON or the PLC CPU is reset, the servo
parameters stored in the flash ROM is transmitted to the buffer memory.
When the servo parameter is written in the flash ROM, it is unnecessary to use a
setup from the PLC program.
Servo parameter of the buffer memory
The following shows details about the operation timing and details the servo
parameter transfer of the buffer memory.
Buffer memory
QD75MH
data setting
power ON
Communication
start valid
1
Indefinite value
Operation details
(1) Servo parameter transfers when servo amplifier had started and the power
supply of QD75MH is turned ON.
(a) When the servo parameter "
Communication start timing to the servo amplifier: Initialization completion
Transfer the servo parameter
Initialization
PLC CPU
completion
RUN
of QD75MH (A)
2
Value of flash ROM
Servo series" "0" is stored flash ROM.
Pr.100
7 - 18
MELSEC-Q
Servo parameter
PLC READY signal [Y0]
setting from PLC
OFF
ON (B)
program (C)
3
2
Communication
start invalid
Write value by PLC program
(Fig. 7.1 A)
: The data stored (backed
up) in the flash ROM.
t

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd75mh2Qd75mh4

Table of Contents