12 CONTROL SUB FUNCTIONS

12.7 Other functions

12.7.1 Step function

OPR control
Major
positioning
control
Manual
control
: Set when required.
Other functions include the "step function", "skip function", "M code output function",
"teaching function", "target position change function", "command in-position function",
"acceleration/deceleration processing function", "pre-reading start function", "
deceleration start flag function" and "stop command processing for deceleration stop
function" and "follow up processing function". Each function is executed by parameter
setting or PLC program creation and writing.
The "step function" is used to confirm each operation of the positioning control one by
one.
It is used in debugging work for major positioning control, etc.
A positioning operation in which a "step function" is used is called a "step operation".
In step operations, the timing for stopping the control can be set. (This is called the
"step mode".) Control stopped by a step operation can be continued by setting "step
continue" (to continue the control)" or restarted by setting "restart" in the "step start
information".
The details shown below explain about the "step function".
[1] Relation between the step function and various controls
[2] Step mode
[3] Step start information
[4] Using the step operation
[5] Control details
[6] Precautions during control
[7] Step function settings
[1] Relation between the step function and various controls
The following table shows the relation between the "step function" and various
controls.
Control type
Machine OPR control
Fast OPR control
1-axis linear control
2 to 4-axes linear interpolation control
Position
1-axis fixed-feed control
control
2 to 4- axes fixed-feed control
(interpolation)
2-axis circular interpolation control
1 to 4- axes Speed control
Speed-position switching control
Position-speed switching control
Current value changing
Other
JUMP instruction, NOP instruction,
control
LOOP to LEND
JOG operation, Inching operation
Manual pulse generator operation
: Setting not possible
Step function
12 - 61
MELSEC-Q
Step applicability
Step operation not possible
Step operation possible
Step operation not possible
Step operation possible
Step operation not possible
Step operation not possible