Mitsubishi Electric QD75MH1 User Manual page 657

Type qd75mh positioning module
Table of Contents

Advertisement

12 CONTROL SUB FUNCTIONS
Setting item
Stop command
processing for
Cd.42
deceleration stop
selection
For details of the setting details, refer to Section 5.7 "Control data list".
[3] Setting method
To use the "stop command processing for deceleration stop function", set the
following control data in a PLC program.
The set data are made valid as soon as they are written to the buffer memory.
The PLC ready signal [Y0] is irrelevant.
Setting
value
Set the stop command processing for
deceleration stop function.
0: Deceleration curve re-processing
1: Deceleration curve continuation
Setting details
12 - 100
MELSEC-Q
Buffer memory address
1907