Mitsubishi Electric QD75MH1 User Manual page 239

Type qd75mh positioning module
Table of Contents

Advertisement

5 DATA USED FOR POSITIONING CONTROL
Storage item
Deceleration start flag
Md.48
OPR re-travel value
Md.100
Real current value
Md.101
Deviation counter value
Md.102
Motor rotation speed
Md.103
Motor current value
Md.104
"1" is stored when the constant speed status or acceleration status switches to
the deceleration status during position control whose operation pattern is
"Positioning complete".
"0" is stored at the next operation start or manual pulse generator operation
enable.
POINT
This parameter is possible to monitor when "
" is valid.
This area stores the travel distance during the OPR travel to the zero point that
was executed last time.
For setting units
Update timing: 1.7ms
Example) mm
(Buffer memory
This area stores the present value (feed present value – deviation counter droop
pulses).
Update timing: 1.7ms
Example) mm
(Buffer memory
This area stores the difference between the feed present and the actual present
value.
(Buffer memory details) PLS
Update timing: 1.7ms
This area stores the present rotation speed of the servomotor.
(Buffer memory
0.1) rpm
Update timing: 1.7ms
This area stores the present motor current value of the motor.
(Buffer memory
0.1) %
Update timing: 1.7ms
5 - 142
Storage details
Deceleration start flag valid
Cd.41
0.1) µm
0.1) µm
MELSEC-Q