5 DATA USED FOR POSITIONING CONTROL
Storage item
Servo status
Md.108
Regenerative load ratio
Md.109
Effective load torque
Md.110
Peak torque ratio
Md.111
This area stores the servo status.
Zero point pass
Turns ON if the zero point of the encoder has been passed even once.
Zero speed
Turns ON when the motor speed is lower than the servo parameter "zero speed."
READY ON
Indicates the ready ON/OFF.
Servo ON
Indicates the servo ON/OFF.
Servo alarm
Turn ON during the servo alarm.
In-position
The dwell pulse turns ON within the servo parameter "in-position."
Torque limit
Turns ON when the servo amplifier is having the torque restricted.
Absolute position lost
Turns ON when the servo amplifier is lost the absolute position.
Servo warning
Turn ON during the servo warning.
Update timing : 1.7ms
The rate of regenerative power to the allowable regenerative power is indicated
as a percentage.
When the regenerative option is used, the rate to the allowable regenerative
power of the option is indicated.
(Buffer memory) %
Update timing: 1.7 ms
The continuous effective load torque is indicated.
The average value of the load rates for the past 15 seconds to the rated torque is
stored as a percentage, rated torque being 100%.
(Buffer memory) %
Update timing: 1.7 ms
The maximum torque is indicated. (Holding value)
The peak values for the past 15 seconds are indicated, rated torque being 100%.
(Buffer memory) %
Update timing: 1.7 ms
5 - 146
Storage details
MELSEC-Q