5 DATA USED FOR POSITIONING CONTROL
Setting item
Cd.100 Servo OFF command
Cd.101 Torque output setting value
Cd.108 Gain changing command
Turns OFF each axis servo.
POINT
When you want to turn ON the servo for two to four axes with only the servo for
one axis turned OFF, write "1" to storage buffer memory address 1551 and then
turn ON all axis servo ON (Y1) signal.
Sets the torque output value.
POINT
If the " Cd.101 Torque output setting value" is "0", the "
setting value" will be its value.
If a value beside "0" is set in the " Cd.101 Torque output setting value", the
torque generated by the servomotor will be limited by that value.
The "
Pr.17
Torque limit setting value" of the servo adjustment parameter
torque output setting value becomes effective at the PLC ready signal rising
edge.
The " Cd.101 Torque output setting value" (refer to the start) axis control data
can be changed at all times. Therefore in the " Cd.101 Torque output setting
value" is used when you must change.
(Refer to Section 12.5.4 "Torque change function".)
The command required to carry out "gain changing" of the servo amplifier from
QD75MH.
POINT
If the setting is other than
with the setting regard as
changing"
(Refer to the servo amplifier instruction manual.)
5 - 170
Setting details
0
and
1
, operation is performed in the
"
"
"
"
0
.
"
"
MELSEC-Q
Pr.17
Torque limit
gain
"