9 MAJOR POSITIONING CONTROL
Setting item
Da.1 Operation pattern
Da.2 Control system
Acceleration time
Da.3
No.
Deceleration time
Da.4
No.
Axis to be
Da.5
interpolated
Positioning address/
Da.6
movement amount
Da.7 Arc address
Da.8 Command speed
Da.9 Dwell time
M code
Da.10
Refer to Section 5.3 "List of positioning data" for information on the setting details.
Positioning data setting example
[Reference axis and interpolation axis are designated as axis 1 and axis 2,
respectively.]
The following table shows setting examples when "2-axis circular interpolation
control with sub point designation (INC circular sub)" is set in positioning data No.
1 of axis 1. (The required values are also set in positioning data No. 1 of axis 2.)
Axis 1
Axis 2
Axis
(reference
(interpolation
axis) setting
axis) setting
example
example
Positioning
complete
INC circular
sub
1
0
2
8000.0 µ m
6000.0 µ m
4000.0 µ m
3000.0 µ m
6000.00
mm/min
500ms
10
POINT
Da.8
Set a value in "
Command speed" so that the speed of each axis does not
Pr.8
exceed the "
Speed limit value". (The speed limit does not function for the
speed calculated by the QD75MH during interpolation control.)
Set "Positioning complete" assuming the next positioning
data will not be executed.
Set incremental system, 2-axis circular interpolation control
with sub point designation.
Designate the value set in " Pr.25
as the acceleration time at start.
Designate the value set in " Pr.10
as the deceleration time at deceleration.
Set the axis to be interpolated (partner axis).
If the self-axis is set, an error will occur.
Set the movement amount. (Assuming that the " Pr.1
Unit setting" is set to "mm".)
Set the sub point address. (Assuming that the " Pr.1
setting" is set to "mm".)
Set the speed during movement. (Designate the composite
speed in " Pr.20
method".)
Set the time the machine dwells after the positioning stop
(pulse output stop) to the output of the positioning complete
signal.
Set this when other sub operation commands are issued in
combination with the No. 1 positioning data.
9 - 59
MELSEC-Q
Setting details
Acceleration time 1"
Deceleration time 0"
Interpolation speed designation
Unit