5 DATA USED FOR POSITIONING CONTROL
Setting item
Cd.16
Inching movement amount
Cd.17
JOG speed
Cd.18
Interruption request during
continuous operation
•
Use this data item to set the amount of movement by inching.
•
The machine performs a JOG operation if "0" is set.
•
Set a value within the following range:
mm
Pr.1
-1
(×10
µm)
Setting range
0 to 65535
•
Use this data item to set the JOG speed.
•
Set a value within the following range:
mm
Pr.1
×
-2
(
10
mm/min)
0 to
Setting range
2000000000
: When "
Pr.83
Speed control 10 x multiplier setting for degree axis" is valid,
this will be the setting range 0 to 2000000000 ( × 10
•
To interrupt a continuous operation, set "1" to this data item.
•
After processing the interruption request ("1"), the QD75MHutomatically resets the
value to "0".
5 - 158
Setting details
inch
degree
-5
-5
(×10
inch)
(×10
degree)
0 to 65535
0 to 65535
inch
Degree
×
-3
×
-3
(
10
inch/min)
(
10
degree/min)
0 to
0 to
2000000000
2000000000
-2
degree/min).
MELSEC-Q
PLS
(PLS)
0 to 65535
PLS
(PLS/s)
0 to 50000000