5 DATA USED FOR POSITIONING CONTROL
Setting item
Cd.36
Step start information
Cd.37
Skip command
Cd.38
Teaching data selection
Cd.39
Teaching positioning data No.
Cd.40
ABS direction in degrees
During a step operation, this data item determines whether the operation is
continued or restarted.
To skip the current positioning operation, set "1" in this data item.
This data item specifies the teaching result write destination.
This data item specifies data to be produced by teaching.
If a value between 1 and 600 is set, a teaching operation is done.
The value is cleared to "0" when the QD75MH is nitialized, when a teaching
operation completes, and when a illegal value (601 or higher) is entered.
This data item specifies the ABS moving direction carrying out the position control
when "degree" is selected as the unit.
5 - 168
Setting details
MELSEC-Q