12 CONTROL SUB FUNCTIONS

12.5.4 Torque change function

The "torque change function" is used to change the torque limit value during torque
limiting.
The torque limit value during torque limiting is normally the value set in the "
Torque limit setting value" or " Cd.101 Torque output setting value" that was
previously set in the parameters. However, by setting the new torque limit value in the
axis control data "
Cd.22
generated by the servomotor during control can be limited with the new torque value.
Cd.22
(The "
New torque value" is validated when written to the QD75MH.)
The details shown below explain about the "torque change function".
[1] Control details
[2] Precautions during control
[3] Setting the torque change function start signal
New torque value", and writing it to the QD75MH, the torque
12 - 56