Detailed Parameters 2 - Mitsubishi Electric QD75MH1 User Manual

Type qd75mh positioning module
Table of Contents

Advertisement

5 DATA USED FOR POSITIONING CONTROL

5.2.4 Detailed parameters 2

Item
Pr.25
Acceleration time 1
Pr.26
Acceleration time 2
Pr.27
Acceleration time 3
Pr.28
Deceleration time 1
Pr.29
Deceleration time 2
Pr.30
Deceleration time 3
Pr.31
JOG speed limit value
Pr.32
JOG operation acceleration
time selection
Pr.33
JOG operation deceleration
time selection
Setting value, setting range
Value set with peripheral device
1 to 8388608 (ms)
The setting range differs depending on the "
Here, the value within the [Table 1] range is set.
[Table 1] on right page
0:
Pr.9
Acceleration time 0
1:
Pr.25
Acceleration time 1
2:
Pr.26
Acceleration time 2
3:
Pr.27
Acceleration time 3
Pr.10
0:
Deceleration time 0
1:
Pr.28
Deceleration time 1
Pr.29
2:
Deceleration time 2
3:
Pr.30
Deceleration time 3
Pr.25 Acceleration time 1 to Pr.27 Acceleration time 3
These parameters set the time for the speed to increase from zero to the speed
Pr.8
limit value (
) during a positioning operation.
Pr.28 Deceleration time 1 to Pr.30 Deceleration time 3
These parameters set the time for the speed to decrease from the speed limit
Pr.8
value (
) to zero during a positioning operation.
Value set with PLC
program
1 to 8388608 (ms)
Pr.1
Unit setting".
0
1
2
3
0
1
2
3
5 - 38
MELSEC-Q
Setting value buffer memory
Default
address
value
Axis 1 Axis 2 Axis 3 Axis 4
36
186
336
37
187
337
38
188
338
39
189
339
40
190
340
41
191
341
1000
42
192
342
43
193
343
44
194
344
45
195
345
46
196
346
47
197
347
48
198
348
20000
49
199
349
0
50
200
350
0
51
201
351
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501

Hide quick links: