12 CONTROL SUB FUNCTIONS

12.4.2 Torque limit function

OPR
control
Major
positioning
control
Manual
control
– : Setting not required (Setting value is invalid. Use the initial values or setting values
The "torque limit function" limits the generated torque to a value within the "torque limit
value" setting range when the torque generated in the servomotor exceeds the "torque
limit value".
The "torque limit function" protects the deceleration function, limits the power of the
operation pressing against the stopper, etc. It controls the operation so that
unnecessary force is not applied to the load and machine.
The details shown below explain about the "torque limit function".
[1] Relation between the torque limit function and various controls
[2] Control details
[3] Precautions during control
[4] Setting the torque limit function
[1] Relation between the torque limit function and various controls
The following table shows the relation of the "torque limit function" and various
controls.
Control type
Machine OPR control
Fast OPR control
1-axis linear control
2 to 4-axes linear
interpolation control
Position
1-axis fixed-feed control
control
2 to 4-axes fixed-feed
control (interpolation)
2-axis circular interpolation
control
1 to 4-axes Speed control
Speed-position switching control
Position-speed switching control
Current value changing
Other
JUMP instruction, NOP
control
instruction, LOOP to
LEND
JOG operation, Inching operation
Manual pulse generator operation
: Set when required (Set to " – " when not used.)
within a range where no error occurs.)
: Shows the torque limit value when "
Torque limit
function
Cd.22
New torque value" is set to "0".
12 - 25
MELSEC-Q
Torque limit value
"
Pr.17
Torque limit setting
value" or " Cd.101 Torque
output setting value".
After the "
Pr.47
Creep
speed" is reached, this value
becomes the "
Pr.54
torque limit value".
"
Pr.17
Torque limit setting
value" or " Cd.101 Torque
output setting value".
Setting value is invalid.
"
Pr.17
Torque limit setting
value" or " Cd.101 Torque
output setting value".
OPR