Mitsubishi Electric QD75MH1 User Manual page 347

Type qd75mh positioning module
Table of Contents

Advertisement

7 MEMORY CONFIGURATION AND DATA PROCESS
Buffer memory area configuration
Servo parameter area
Use of address Nos. skipped above is prohibited. If used, the system may not operate correctly.
POINT
When the parameter of the servo amplifier side is changed, it is transmitted to the servo memory area
in the buffer memory after the QD75MH is read automatically with parameters.
(1) When changing the servo parameters by the auto tuning.
(2) When the servo parameter is changing after the MR-configurator is connected directly with the servo
amplifier.
Basic setting parameter area
Gain • filter setting parameter
area
Expansion setting parameter
area
Input/output setting parameter
area
Buffer memory address
Axis 1
Axis 2
30100 to
30300 to
30115
30315
30119 to
30319 to
30152
30352
30164 to
30364 to
30184
30384
30202 to
30402 to
30204
30404
7 - 6
MELSEC-Q
Axis 3
Axis 4
30500 to
30700 to
30515
30715
30519 to
30719 to
30552
30752
30564 to
30764 to
30584
30784
30602 to
30802 to
30604
30804
Writing
possibility
Possible

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd75mh2Qd75mh4

Table of Contents