Functions, Monitoring, and Protective Functions
9.2 Drive Functions
Function diagram
FP 8014
Parameter
• r0036
• r0037
• p0115
• p0230
• p0290
• p1082
• r2135.13
• r2135.15
9.2.12

Pulse frequency wobbling

Description
Pulse frequency wobbling is when the pulse frequency is varied slightly according to a
statistical process. The average pulse frequency value is still the value set; the statistical
variation of the instantaneous value results in a modified noise spectrum.
This procedure reduces the subjectively noticeable motor noise, especially for the relatively
low pulse frequencies set in the factory.
Pulse frequency wobbling is activated with p1810.2 = 1. The amplitude of the static wobbling
signal can be set in the range from 0% to 20% via p1811.
For units connected in parallel, pulse frequency wobbling is activated automatically during
commissioning.
456
Signals and monitoring functions - thermal monitoring power unit
Power unit overload I2t
CO: Power unit temperatures
Sampling times for internal control loops
Drive filter type, motor side
Power unit overload response
Maximum speed
Fault thermal overload power unit
Thermal overload in power unit alarm