Siemens SINAMICS G150 Operating Instructions Manual page 493

Converter cabinet units 75 kw to 1500 kw
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Figure 9-16
Control and status messages for extended brake control
Table 9- 10
Control of extended brake control
Signal name
Enable speed setpoint
Enable setpoint 2
Unconditionally release holding brake
Enable speed controller
Unconditionally apply holding brake
Converter cabinet units
Operating Instructions, 03/2012, A5E03263466A
Example: Service brake on a crane drive
Binector input
p1142 BI: Enable speed setpoint
p1152 BI: Setpoint 2 enable
p0855 BI: Unconditionally release
holding brake
p0856 BI: Enable speed controller
p0858 BI: Unconditionally apply holding
brake
Functions, Monitoring, and Protective Functions
Control word sequence
control/interconnection parameters
STWA.6
p1152 = r899.15
STWA.7
STWA.12
STWA.14
9.3 Extended functions
491