Siemens SINAMICS G150 Operating Instructions Manual page 143

Converter cabinet units 75 kw to 1500 kw
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

CAUTION
The surface temperature of the braking resistors may exceed 80 °C.
Table 4- 50
Dimensions of the braking resistors
Unit
Width
mm
Height
mm
Depth
mm
Figure 4-21
Dimension drawing for braking resistor (25 kW)
Figure 4-22
Dimension drawing for braking resistor (50 kW)
Converter cabinet units
Operating Instructions, 03/2012, A5E03263466A
25 kW resistor (option L61)
740
605
485
Electrical installation
4.11 Other connections
50 kW resistor (option L62)
810
1325
485
141