Functions, Monitoring, and Protective Functions
9.2 Drive Functions
Functions, which cannot be executed when know-how protection is active
The following functions cannot be executed when know-how protection is active:
● Download
● Export/import
● Trace function
● Function generator
● Measuring functions
● Automatic controller setting
● Stationary/rotating measurement
● Clear fault buffer
Setting parameters, which can only be read when know-how protection is active
The following setting parameters cannot be changed, but can be read, when know-how
protection is activated:
● Motor parameters (p0100, p0300, p0304, p0305, p0349)
● Data sets (p0120, p0130, p0140, p0150, p0170, p0180)
● Encoder type (p0400)
● Reference quantities (p2000, p2001, p2002, p2003, p2005, p2006, p2007)
These parameters are shown in STARTER in the expert list with a gray background.
Note
List of the setting parameters, which can only be read when know-how protection is active
A list of the setting parameters, which can only be read when know-how protection is
activated, are provided in the List Manual.
The list has the designation "KHP_ACTIVE_READ".
AOP30 with activated know-how protection
When know-how protection is activated, the AOP30 operator panel does not show protected
parameters.
The setting parameters, which can only be read when know-how protection is active, are
displayed. An attempt to change such an adjustable parameter, will be rejected and an error
message displayed.
9.2.20.2

Activating know-how protection

Know-how protection can be activated via STARTER in the online mode.
472
Converter cabinet units
Operating Instructions, 03/2012, A5E03263466A