Technical data

11.4 Pulse frequency and current reduction

11.4
Pulse frequency and current reduction
Relationship between pulse frequency, temperature and output base-load current
Figure 11-1
Table 11- 2
Rated power
based on HO
1.5 kW @45 °C
1.1 kW @55 °C
11.5

Electromagnetic compatibility of the converters

11.5.1

Electromagnetic compatibility

Electromagnetic compatibility (EMC)
All manufacturers/assemblers of electrical units which "perform an essentially complete
function and are marketed as a single unit designed for the end-user", must comply with the
EMC Directive 89/336/EEC.
There are three ways for the manufacturer/assembler to verify compliance:
Self-certification
The manufacturer declares that the European standards applicable to the electrical
environment for which the unit is intended are satisfied. Only standards which have been
officially published in the official journal of the European Union are allowed to be cited in the
manufacturer's declaration.
238
Power derating in relation to the ambient temperature and pulse frequency
Current reduction depending on pulse frequency
Rated output current at pulse frequency of
4 kHz
6 kHz
3.9
3.9
3.5
2.8
8 kHz
10 kHz
3.9
3.6
2.2
1.6
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257324B AE
12 kHz
14 kHz
16 kHz
3.3
2.7
1.1
0.5
SIMATIC ET 200pro FC-2 converter
2.2
0.0