7.3.3

Slip compensation

Description
Slip compensation essentially keeps the speed of induction motors constant irrespective of
the load (M
For an increase in the load from M
so that the resulting frequency and therefore the motor speed remains constant. For a
decrease in the load from M
accordingly.
If a motor holding brake is applied, a setting value can be specified at the slip compensation
output via p1351. If parameter p1351 > 0 then the slip compensation is switched on
automatically (p1335 = 100%).
Figure 7-10
Function diagram
FP 6310
Parameters
• r0330
• p1334
• p1335
• p1336
• r1337
• p1351
Converter cabinet units
Operating Instructions, 03/2012, A5E03263466A
or M
).
1
2
to M
2
Slip compensation
Resonance damping and slip compensation
Rated motor slip
Slip compensation start frequency
Slip compensation
p1335 = 0.0%: slip compensation is deactivated.
p1335 = 100.0%: slip is fully compensated.
Slip compensation limit value
Actual slip compensation
CO: Motor holding brake start frequency
Setpoint channel and closed-loop control
to M
, the setpoint frequency is automatically increased
1
2
, the setpoint frequency is automatically decreased
1