Commissioning
5.3 Procedure for commissioning via STARTER
Assigning the IP address and the name via STARTER, "Accessible nodes" function
Use the STARTER to assign an IP address and a name to the Ethernet interface.
● Connect the PG/PC and the Control Unit using an Ethernet cable.
● Switch on the Control Unit.
● Open STARTER.
● Either create a new project or open an existing project
● A search is performed for available nodes in Ethernet via Project -> Accessible nodes or
● The SINAMICS drive object is detected and displayed as a bus node with IP address
Figure 5-33
Accessible nodes
● Mark the bus node entry and select the displayed menu item "Edit Ethernet node" with
● In the following "Edit Ethernet node" screen, enter the device name for the Ethernet
interface (e.g. "drive1") and click the "Assign name" button. Enter the IP address (e.g.
169.254.11.10) in the IP configuration and specify the subnet screen (e.g.
255.255.255.0). Then click the "Assign IP configuration" button and close the mask.
236
the "Accessible nodes" button.
169.254.11.22 and without name.
the right mouse button.
Converter cabinet units
Operating Instructions, 03/2012, A5E03263466A