SoftPLC [50]
Description:
By means of this parameter, it is possible to visualize the status of the 8 digital inputs (DI9 to DI16) of the IOC-01,
IOC-02 or IOC-03 module.
The indication is done by means of the numbers 1 and 0, representing respectively the "Active" and "Inactive" states of the
inputs. The state of each input is considered as one digit in the sequence where DI9 represents the least significant digit.

18.2.2 Digital Outputs [41]

At the IOC-01, 4 relay contact digital outputs (NO relay contact) are available, DO6 to DO9. At the IOC-02,
8 open collector type digital outputs are available, DO6 to DO13. The module IOC-03 provides 7 digital
outputs type PNP , galvanically isolated of 500 mA each.
P0026 – DO6 to DO13 Status
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
By means of this parameter, it is possible to visualize the status of the IOC-01 module 4 digital outputs, the status of
the 8 digital outputs of module IOC-02 or the status of the 7 digital outputs of the module IOC-03.
The indication is done by means of the numbers "1" and "0", representing respectively the "Active" and "Inactive"
states of the outputs. The state of each output is considered as one digit in the sequence where DO6 represents the
least significant digit.
Note: When the IOC-01 module is used, the indications of bits DO10 to DO13 stay inactive. When the IOC-03
module is used, the indication of bit DO13 stay inactive.
18
18-2
Bit 0 = DO6
Bit 1 = DO7
Bit 2 = DO8
Bit 3 = DO9
Bit 4 = DO10
Bit 5 = DO11
Bit 6 = DO12
Bit 7 = DO13
RO
01 PARAMETER GROUPS
41 Digital Outputs
or
07 I/O CONFIGURATION
41 Digital Outputs
Factory
-
Setting: