WEG CFW-11 Programming Manual page 196

V5.8x
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Digital and Analog Inputs and Outputs
Functions
Not used
Run/Stop
General Enable
Fast Stop
FWD Run
REV Run
Start
Stop
FWD/REV
LOC/REM
JOG
Increase E.P .
Decrease E.P .
Multispeed
Ramp 2
Speed/Torque
JOG+
JOG-
No Ext. Alarm
No Ext. Fault
Reset
PLC Use
Manual/Auto
Disable FlyStart
DC Link Regul.
Program. Off
Load User 1/2
Load User 3
DO2 Timer
DO3 Timer
Trace Function
* Factory setting
Some notes regarding the Digital Input functions are presented next.
- Run/Stop: In order to assure the correct operation of this function, it is necessary to program P0224 and/or
P0227 in 1.
- Fast Stop: The "Run/Stop = Stop" command is executed with null deceleration ramp, regardless of the P0101
or P0103 setting. Its use is not recommended with V/f and VVW control modes.
- Increase E.P . and Decrease E.P . (Electronic Potentiometer): They are active when +24 V is applied (for Increasing
E.P .) or 0 V (for Decreasing E.P .) at the respective input programmed for that function. It is also necessary to program
P0221 and/or P0222 in 7. Refer to the
- Local/Remote: When programmed, this function activates "Local" when 0 V is applied to the input, and "Remote"
when +24 V are applied. It is also necessary to program P0220 = 4 (DIx).
- Speed/Torque: This function is valid for P0202 = 3 or 4 (Sensorless Vector Control or Vector with Encoder), and
"Speed" is selected with 0 V applied to the input, whereas "Torque" by applying 24 V.
13
13-14
Table 13.9 - Digital input functions
P0263
P0264
(DI1)
(DI2)
0, 13 and 23 0, 13 and 23 0*, 13 and 23 0* and 23
1*
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8*
9
9
10
10
11
11
12
12
-
-
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
24
24
25
25
26
26
27
27
28
28
29
29
30
30
31
31
Section 12.5 ELECTRONIC POTENTIOMETER [37] on page
P0265
P0266
P0267
(DI3)
(DI4)
(DI5)
0 and 23
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
10
10
10*
11
11
11
12
12
12
-
13
13
14
14
14
15
15
15
16
16
16
17
17
17
18
18
18
19
19
19
20
20
20
21
21
21
22
22
22
24
24
24
25
25
25
26
26
26
27
27
27
28
28
28
29
29
29
30
30
30
31
31
31
P0268
P0269
P0270
(DI6)
(DI7)
(DI8)
0 and 23
0*, 13 and 23 0*, 13 and 23
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
-
14*
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
24
24
25
25
26
26
27
27
28
28
29
29
30
30
31
31
12-9.
1
2
3
4
5
6
7
8
9
10
11
12
-
14
15
16
17
18
19
20
21
22
24
25
26
27
28
29
30
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents