Trace Function [52]
P0560 – Trace Available Memory
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
It shows the amount of memory available for storing Trace Function points. The range from 0 to 100 % indicates that
from 0 to 15 KB are available for the Trace Function.
Sharing of memory with the SoftPLC:
The memory for the Trace Function is shared with the memory for the SoftPLC applicative.
- If P1000=0 (there is no SoftPLC applicative), it is possible to use all the memory area for the Trace Function. In
this case, P0559 = P0560.
- If P1000>0 (there is SoftPLC applicative in the inverter), P0560 will show the smallest value between P0559 and
0the actual available memory (that will be 100 % minus the memory used by the SoftPLC applicative).
In order to be able to use the Trace Function, the user must adjust P0559 with a value greater than 0 %, and equal or
less than the P0560 indication. If P0559 > P0560 and the user wishes to use more memory for the Trace Function,
then the SoftPLC applicative must be erased by means of the parameter P1001.
NOTE!
If P0559 > P0560, then distortion in the observed signals may occur.
Function, then the SoftPLC applicative must be erased by means of the parameter P1001.
P0561 – CH1: Trace channel 1
P0562 – CH2: Trace channel 2
P0563 – CH3: Trace channel 3
P0564 – CH4: Trace channel 4
Adjustable
Range:
19
Properties:
Access groups
via HMI:
19-4
0 to 100 %
RO
01 PARAMETER GROUPS
52 Trace Function
0 = Not selected
1 = Speed Reference
2 = Motor Speed
3 = Motor Current
4 = DC Link Voltage
5 = Motor Frequency
6 = Motor Voltage
7 = Motor Torque
8 = Process Variable
9 = PID Setpoint
10 = AI1
11 = AI2
12 = AI3
13 = AI4
01 PARAMETER GROUPS
52 Trace Function
Factory
Setting:
Factory
P0561 = 1
Setting:
P0562 = 2
P0563 = 3
P0564 = 0