Read Only Parameters [09]
P0800 – Temperature U-B1/IGBT U1
P0801 – Temperature V-B1/IGBT V1
P0802 – Temperature W-B1/IGBT W1
P0803 – Temperature U-B2/IGBT U2
P0804 – Temperature V-B2/IGBT V2
P0805 – Temperature W-B2/IGBT W2
P0806 – Temperature U -B3/IGBT U3
P0807 – Temperature V-B3/IGBT V3
P0808 – Temperature W-B3/IGBT W3
P0809 – Temperature U-B4/IGBT U4
P0810 – Temperature V-B4/IGBT V4
P0811 – Temperature W-B4/IGBT W4
P0812 – Temperature U-B5/IGBT U5
P0813 – Temperature V-B5/IGBT V5
P0814 – Temperature W-B5/IGBT W5
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
These reading parameters indicate, in Celsius degrees (ºC), the internal temperature of the IGBTs of each phase.
In a modular drive, this information is shown for each Book, and for frame H it is shown for each IGBT module.
The indication resolution is 0.1ºC (32.18 ºF).
P0815 – Current U-B1/IGBT U1
16
P0816 – Current V-B1/IGBT V1
16-16
-20.0 to 150.0°C
CFG
01 PARAMETER GROUPS
45 Protections
09 Read only
Factory
Setting: