WEG CFW-11 Programming Manual page 209

V5.8x
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

P0287 – Hysteresis for Nx and Ny
Adjustable
0 to 900 rpm
Range:
Properties:
Access groups
07 I/O CONFIGURATION
via HMI:
Description:
It is used in the N > Nx and N < Ny functions of the digital and relay outputs.
P0288 – Nx Speed
Adjustable
0 to 18000 rpm
Range:
P0289 – Ny Speed
Adjustable
0 to 18000 rpm
Range:
Properties:
Access groups
07 I/O CONFIGURATION
via HMI:
Description:
They are used in the N* > Nx, N > Nx, and N < Ny functions of the digital and relay outputs.
P0290 – Ix Current
Adjustable
0 to 2 x I
Range:
Properties:
Access groups
07 I/O CONFIGURATION
via HMI:
Description:
It is used in the Is > Ix and Ix < Ix functions of the digital and relay outputs.
P0291 – Zero Speed Zone
Adjustable
0 to 18000 rpm
Range:
Properties:
Access groups
07 I/O CONFIGURATION
via HMI:
41 Digital Outputs
41 Digital Outputs
nom-ND
41 Digital Outputs
35 Zero Speed Logic
Digital and Analog Inputs and Outputs
Factory
Setting:
or
01 PARAMETER GROUPS
41 Digital Outputs
Factory
Setting:
Factory
Setting:
or
01 PARAMETER GROUPS
41 Digital Outputs
Factory
Setting:
or
01 PARAMETER GROUPS
41 Digital Outputs
Factory
Setting:
or
01 PARAMETER GROUPS
41 Digital Outputs
18 rpm
(15 rpm)
120 rpm
(100 rpm)
1800 rpm
(1500 rpm)
1.0 x I
nom-ND
18 rpm
(15 rpm)
13
13-27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents