Digital and Analog Inputs and Outputs
s) STOP
Only on pulse in the Dix disables the inverter.
t) SAFETY SWITCH
Only one inactive pulse in the Dix disables the inverter.

12.6 INPUT FOR INFRARED RECEIVER

The CFW100-IOADR accessory uses an infrared remote control to command the inverter. The RC-5 protocol
(Philips) was used for the communication of the control with the accessory. The information about the status of
the keys is available in parameter P840 of the CFW100.
P840 – IR Control Key Status
Adjustable
Range:
12
Properties:
Description:
This parameter enables to view the status of the infrared control keys of the CFW100.
For further details, refer to the Installation, Configuration and Operation Guide of the CFW100-IOADR I/O
Expansion Module.

12.7 DIGITAL OUTPUTS

The CFW100 can activate up to three relay digital outputs (DO1 to DO3) – one with the CFW100-IOAR accessory
or three with the CFW100-IOADR accessory connected to the product. The configuration of the digital output
parameters is according to the detailed description below.
12-16 | CFW100
Output
frequency
DIx - Parar
Figure 12.15: Example the stop function
Output
frequency
DIx - Safety
switch
Figure 12.16: Example of the Emergency function
2 or 802 = On/Off
6 or 806 = Arrow down
8 or 808 = Arrow up
9 or 809 = Invert/Change
B or 80B = Program
F or 80F = Special Function 01
10 or 810 = Special Function 02
11 or 811 = Special Function 03
ro
Acceleration
ramp
Time
Active
Inactive
Time
Acceleration
ramp
Time
Active
Inactive
Time
Return
Advance
Factory
Setting: