P0216 – HMI Display Contrast
Adjustable
0 to 37
Range:
Properties:
Access groups
01 PARAMETER GROUPS
via HMI:
Description:
It allows setting the keypad (HMI) display contrast level. Higher values configure a higher contrast level.

5.5 DATE AND TIME SETTING

Seq.
Action/Result
- Monitoring Mode.
- Press "Menu"
1
(right "soft key").
- The group "00 ALL
PARAMETERS" is already
2
selected.
- The group "01
PARAMETER GROUPS" is
3
selected.
- Press "Select".
- A new list of groups is
showed on the display,
with the group "20
Ramps" selected.
4
- Press
until
the group "30 HMI" is
selected.
- The group "30 HMI" is
selected.
5
- Press "Select".
30 HMI
Display Indication
Ready
0rpm
LOC
0
rpm
0.0
A
0.0
Hz
16:10
Menu
Ready
0rpm
LOC
00 ALL PARAMETERS
01 PARAMETER GROUPS
02 ORIENTED START-UP
03 CHANGED PARAMETERS
Return
16:10
Select
Ready
0rpm
LOC
00 ALL PARAMETERS
01 PARAMETER GROUPS
02 ORIENTED START-UP
03 CHANGED PARAMETERS
Return
16:10
Select
Ready
0rpm
LOC
20 Ramps
21 Speed References
22 Speed Limits
23 V/f Control
Return
16:10
Select
Ready
LOC
0rpm
27 V/f DC Volt.Limit.
28 Dynamic Braking
29 Vector Control
30 HMI
Return
16:10
Select
Figure 5.2 - Date and time adjustment
Programming Basic Instructions
Seq.
Action/Result
- The parameter "Day
P0194" is already
selected.
- If necessary, set P0194
according to the actual
day. Therefore, press
"Select".
- For changing P0194
6
contents
or
.
- Proceed in the same
way for adjusting the
parameters from "Month
P0195" to "Seconds
P0199".
- When P0199 is finished,
the Real Time Clock will
7
be adjusted.
- Press "Return"
(left "soft key").
- Press "Return".
8
- Press "Return".
9
- The display returns to the
Monitoring Mode.
10
Factory
27
Setting:
Display Indication
Ready
0rpm
LOC
Day
P0194:
06
Month
P0195:
10
Return
16:10
Select
Ready
0rpm
LOC
Minutes
P0198:
11
Seconds
P0199:
34
Return
18:11
Select
Ready
0rpm
LOC
27 V/f DC Volt.Limit.
28 Dynamic Braking
29 Vector Control
30 HMI
Return
18:11
Select
Ready
0rpm
LOC
00 ALL PARAMETERS
01 PARAMETER GROUPS
02 ORIENTED START-UP
03 CHANGED PARAMETERS
Return
18:11
Select
Ready
0rpm
LOC
0
rpm
0.0
A
0.0
Hz
18:11
Menu
5-9
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents