18 SOFTPLC [50]

18.1 SOFTPLC

The SoftPLC function allows the frequency inverter to assume PLC (Programmable Logical Controller) functions.
For more details regarding the programming of those functions in the CFW-11, refer to the CFW-11 SoftPLC
manual. The parameters related to the SoftPLC are described next.
P1000 – SoftPLC Status
P1001 – SoftPLC Command
P1002 – Scan Cycle Time
P1010 to P1059 – SoftPLC Parameters
NOTE!
Parameters P1010 to P1019 can be visualized in the Monitoring Mode (Refer to the
HMI [30] on page
SETTINGS on page
NOTE!
When P1011 is a writing parameter and is programmed in P0205, P0206 or P0207, then its
contents can be changed in the Monitoring Menu (Refer to the
IN THE MONITORING MODE SETTINGS on page

18.2 I/O CONFIGURATION [07]

The next digital inputs and outputs are for the SoftPLC exclusive use.

18.2.1 Digital Inputs [40]

The next parameters will be visualized on the HMI when the IOC-01, IOC-02 or IOC-03 module is connected
into the slot 1 (XC41 connector).
P0025 – DI9 to DI16 Status
Adjustable
Bit 0 = DI9
Range:
Bit 1 = DI10
Bit 2 = DI11
Bit 3 = DI12
Bit 4 = DI13
Bit 5 = DI14
Bit 6 = DI15
Bit 7 = DI16
Properties:
RO
Access groups
01 PARAMETER GROUPS
via HMI:
5-4, and
Section 5.6 DISPLAY INDICATIONS IN THE MONITORING MODE
5-10).
40 Digital Inputs
Section 5.6 DISPLAY INDICATIONS
5-10) by using the HMI
or
07 I/O CONFIGURATION
40 Digital Inputs
SoftPLC [50]
Section 5.4
or
key.
Factory
-
Setting:
18-1
18