WEG CFW-11 Programming Manual page 305

V5.8x
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Seq.
Action/Result
- If necessary, change
the content of P0401
according to the rated
motor current. Therefore
14
press "Selec.". This
change will affect P0156,
P0157 and P0158.
- If necessary, change
the content of P0402
according to the rated
motor speed. Therefore
press "Selec.". This
15
change will affect P0122
to P0131, P0133, P0134,
P0208, P0288, P0289
and P0403.
- P0403 is automatically
adjusted according to:
P0403 = P0402 x P0431
16
120
Therefore press "Selec.".
- If necessary, change
the content of P0404
according to the rated
17
motor power. Therefore
press "Selec.".
- This parameter will only
be visible if the encoder
board ENC1 or the PLC11
module is connected to
the inverter.
- If there is an encoder
18
connected to the motor,
change P0405 according
to its number of pulses per
revolution. Therefore press
"Selec.".
Display Indication
Config
0rpm
LOC
Motor Rated Voltage
P0400:
440V
Motor Rated Current
P0401:
13.5 A
Reset
13:48
Select
Config
0rpm
LOC
Motor Rated Current
P0401:
13.5A
Motor Rated Speed
P0402:
1750 rpm
Reset
13:48
Select
Config
0rpm
LOC
Motor Rated Speed
P0402:
1750 rpm
Motor Rated Frequency
P0403:
60 Hz
Reset
13:08
Select
Config
0rpm
LOC
Motor Rated Frequency
P0403:
60 Hz
Motor Rated Power
P0404:
4hp 3kW
Reset
13:48
Select
Config
0rpm
LOC
Motor Rated Power
P0404:
4hp 3kW
Encoder Pulse Number
P0405:
1024 ppr
Reset
13:48
Select
Figure 21.4 - PM vector mode oriented Start-up
Seq.
Action/Result
- Set P0409 according to
the motor data sheet.
Therefore, press "Selec.".
- If the information is not
19
available, keep the setting
equal to zero.
Adjust P0431 equal to 6
for the standard Wmagnet
motor.
Therefore press "Selec.".
20
This change will affect
P0403.
Adjust P0433 according to
the nameplate data.
21
Therefore press "Selec.".
Adjust P0434 according to
the nameplate data.
22
Therefore press "Selec.".
Adjust P0435 according to
the nameplate data.
23
Therefore press "Selec.".
PM Vector Control
Display Indication
Config
0rpm
LOC
Encoder Pulses Number
P0405:
1024 ppr
Stator Resistence
P0409:
0.000 ohm
Reset
13:48
Select
Config
LOC
0rpm
Resistencia Estator
P0409:
0.000 ohm
Numero de Polos
P0431:
6
Reset
13:48
Selec.
Config
0rpm
LOC
Numero de Polos
P0431:
6
Indutancia Lq
P0433:
0.00 mH
Reset
13:48
Selec.
Config
0rpm
LOC
Indutancia Lq
P0433:
0.00 mH
Indutancia Ld
P0434:
0.00 mH
Reset
13:48
Selec.
Config
0rpm
LOC
Indutancia Ld
P0434:
0.00 mH
Constante Ke
P0435:
100.0
Reset
13:48
Selec.
21-17
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents