PM Vector Control
P0442 – Inductance Lq - CT
P0443 – Inductance Lq - CT
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
Adjust them according to the motor nameplate data. If these pieces of information are not available, keep the
default value.
The view of parameters P0433, P0434, P0442 and P0443 will depend on the value set in P0430.
NOTE!
The use of the default value causes:
1. It increases the output current, because the motor in those conditions does not produce the
2. It prevents the motor operation in the field-weakening region.
P0435 – Ke Constant
Adjustable
Range:
Properties:
Access groups
via HMI:
P0444 – Constant Ke – CT
Adjustable
Range:
Properties:
Access groups
via HMI:
Note: ke is the generated voltage constant. It is a characteristic of the motor, which determines the voltage generated
as a function of the motor speed. The used engineering unit is V/krpm (Volts/1000 rpm).
21
21-8
0.0 to 400.0 mH
CFG and PM
01 PARAMETER GROUPS
43 Motor Data
reluctance torque. The increase of the output current may cause increase in the motor temperature.
0 to 600.0
CFG and PM
01 PARAMETER GROUPS
43 Motor Data
0 to 3000
CFG and PM
01 PARAMETER GROUPS
43 Motor Data
Factory
0.0 mH
Setting:
Factory
100.0 V/krpm
Setting:
Factory
100 V/krpm
Setting: