P0810 – Temperature V-B4/IGBT V4
P0811 – Temperature W-B4/IGBT W4
P0812 – Temperature U-B5/IGBT U5
P0813 – Temperature V-B5/IGBT V5
P0814 – Temperature W-B5/IGBT W5
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
These reading parameters indicate, in Celsius degrees (ºC), the internal temperature of the IGBTs of each phase. In
a modular drive, this information is shown for each Book, and in case of frame H it is shown for each IGBT module.
P0832 - Digital Input DIM1 Function
P0833 - Digital Input DIM2 Function
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
These parameters allow configuring the digital inputs DIM1 and DIM2 for the type of fault (1, 2, 3, 4 or 6) or alarm
(5) to be detected. The fault or alarm code will be displayed on the HMI, and the inverter will be disabled when the
selected fault occurs.
15
15-18
-20.0 °C to 150.0 °C
RO
01 PARAMETER GROUPS
45 Protections
0 = Not Used
1 = No External Fault IPS
2 = No Refrigeration Fault
3 = No Braking Overtemperature Fault
4 = No External Rectifier Overtemperature Fault
5 = No External Rectifier Temperature Alarm
6 = No External Rectifier Fault
CFW-11M
01 PARAMETER GROUPS
45 Protections
Factory
Setting:
or
09 READ ONLY PARAMETERS
or
01 PARAMETER GROUPS
40 Digital Inputs
Factory
0