Value obtained from the motor data sheet. If this information is not available, use the factory setting.
P0430 – PM Type
Adjustable
0 = Factory Setting
Range:
1 = Cooling Tower
Properties:
CFG and PM
Access groups
01 PARAMETER GROUPS
via HMI:
Description:
When parameterized for standard Wmagnet motor (P0430 = 0), the parameterization of P0433, P0434 and
P0435 will be permitted. When P0430 = 1, the parameterization of P0442, P0443 and P0444 will be permitted.
P0431 – Number of Motor Pole
Adjustable
2 to 24
Range:
Properties:
PM
Access groups
01 PARAMETER GROUPS
via HMI:
NOTE!
Set this parameter in 6 for the standard Wmagnet motor line (P0402 = 1800 rpm or 3600 rpm).
Other values are possible for special motors.
P0433 – Lq Inductance
P0434 – Ld Inductance
Adjustable
0 to 100.00 mH
Range:
Properties:
PM
Access groups
01 PARAMETER GROUPS
via HMI:
43 Motor Data
43 Motor Data
43 Motor Data
PM Vector Control
Factory
0
Setting:
Factory
6
Setting:
Factory
0.00 mH
Setting: