WEG CFW-11 Programming Manual page 36

V5.8x
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Quick Parameter Reference, Faults and Alarms
0
Parameter
Function
P0947
Fault Number
P0963
Profibus Baud Rate
P0964
Drive Unit Ident.
P0965
Profile Ident. Number
P0967
Control Word 1
P0968
Status Word 1
P1000
SoftPLC Status
P1001
SoftPLC Command
P1002
Scan Cycle Time
P1010
SoftPLC Parameter 1
P1011
SoftPLC Parameter 2
P1012
SoftPLC Parameter 3
P1013
SoftPLC Parameter 4
P1014
SoftPLC Parameter 5
P1015
SoftPLC Parameter 6
P1016
SoftPLC Parameter 7
P1017
SoftPLC Parameter 8
P1018
SoftPLC Parameter 9
P1019
SoftPLC Parameter 10
P1020
SoftPLC Parameter 11
P1021
SoftPLC Parameter 12
P1022
SoftPLC Parameter 13
P1023
SoftPLC Parameter 14
P1024
SoftPLC Parameter 15
P1025
SoftPLC Parameter 16
P1026
SoftPLC Parameter 17
P1027
SoftPLC Parameter 18
0-28
Adjustable Range
Factory Setting
0 to 65535
0 = 9.6 kbit/s
1 = 19.2 kbit/s
2 = 93.75 kbit/s
3 = 187.5 kbit/s
4 = 500 kbit/s
5 = Not Detected
6 = 1500 kbit/s
7 = 3000 kbit/s
8 = 6000 kbit/s
9 = 12000 kbit/s
10 = Reserved
11 = 45.45 kbit/s
0 to 65535
0 to 65535
Bit 0 = ON
Bit 1 = No Coast Stop
Bit 2 = No Quick Stop
Bit 3 = Enable Operation
Bit 4 = Enable Ramp
Generator
Bit 5 = Reserved
Bit 6 = Enable Setpoint
Bit 7 = Fault Acknowledge
Bit 8 = Jog 1
Bit 9 = Reserved
Bit 10 = Control by PLC
Bit 11 ... 15 = Reserved
Bit 0 = Ready To Swtich
On
Bit 1 = Ready To Operate
Bit 2 = Operation Enabled
Bit 3 = Fault Present
Bit 4 = Coast Stop Not
Active
Bit 5 = Quick Stop Not
Active
Bit 6 = Switching On
Inhibited
Bit 7 = Warning Present
Bit 8 = Reserved
Bit 9 = Control By PLC
Bit 10 ... 15 = Reserved
0 = No Application
1 = Install. App.
2 = Incompat. App.
3 = App. Stopped
4 = App. Running
0 = Stop Program
1 = Run Program
2 = Delete Program
0 to 65535 ms
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
User
Properties
Setting
RO
RO
RO
RO
RO
RO
-
RO
0
CFG
-
RO
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
Groups
Pag.
09, 115
17-4
09, 115
17-4
09, 115
17-4
09, 115
17-4
09, 115
17-4
09, 115
17-4
09, 50
18-1
50
18-1
09, 50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1
50
18-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents