Read Only Parameters [09]
P0003 – Motor Current
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
It indicates the inverter output current in Amps (A), by means of 1.0 second filter.
P0004 – DC Link Voltage (U
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
It indicates the DC Link actual dc voltage in volts (V), by means of 0.1 second filter.
P0005 – Motor Frequency
Adjustable
Range:
Properties:
Access groups
via HMI:
Description:
It indicates the inverter output frequency in Hertz (Hz).
P0006 – Inverter Status
Adjustable
Range:
16
Properties:
Access groups
via HMI:
16-2
0.0 to 4500.0 A
RO
09 READ ONLY PARAMETERS
)
d
0 to 2000 V
RO
09 READ ONLY PARAMETERS
0.0 to 1020.0 Hz
RO
09 READ ONLY PARAMETERS
0 = Ready
1 = Run
2 = Undervoltage
3 = Fault
4 = Self-Tuning
5 = Configuration
6 = DC-Braking
7 = STO
RO
09 READ ONLY PARAMETERS
Factory
Setting:
Factory
Setting:
Factory
Setting:
Factory
Setting: