Example
# Set the summer time for z2 that starts at 06:00:00 on 08/06/2002 and ends at
06:00:00 on 01/09/2002 with the time adding 1 hour.
<Quidway> clock summer-time z2 one-off 06:00:00 2002/06/08 06:00:00 2002/09/01
01:00:00
# Set the summer time for z2 that starts at 06:00:00 on 08/06 and ends at 06:00:00 on
01/09 in each year from 2002 on with the time adding 1 hour.
<Quidway> clock summer-time z2 repeating 06:00:00 2002/06/08 06:00:00 2002/09/01
01:00:00

4.1.3 clock timezone

Syntax
clock timezone zone_name { add | minus } HH:MM:SS
undo clock timezone
View
User view
Parameter
zone_name: Name of the time zone, which is a character with the length ranging 1 to
32.
add: The time is adding compared with the UTC.
minus: The time is minus compared with the UTC.
HH:MM:SS: Time (hour/minute/second).
Description
Using clock timezone command, you can set the information of the local time zone.
Using undo clock timezone command, you can restore to the default Universal Time
Coordinated (UTC) time zone.
After the configuration takes effect, the display clock command can be used to check
it. Besides, the time of the log or debug information uses the local time after the
adjustment of the time zone and summer time.
For the related command, see clock summer-time.